Varian Medical Systems

TrueBeam Linear Accelerator

High-throughput LINAC for IMRT, VMAT and SBRT.

TrueBeam Linear Accelerator — Treatment room

High-dose radiotherapy delivered 4× faster — without compromise on precision.

TrueBeam is Varian's flagship linear accelerator, delivering radiation therapy at speeds up to 4× faster than conventional systems. Many SBRT treatment courses complete in under two minutes of beam-on time. Integrated kV/MV CBCT and OBI imaging verify patient position at every fraction — ensuring sub-millimetre daily accuracy across a full caseload from complex SRS and SBRT to routine palliative treatments. TrueBeam is the workhorse LINAC for high-volume African cancer centres where throughput, precision and application range must all be maximised.

TrueBeam Linear Accelerator

Speed

TrueBeam delivers dose at up to 2,400 MU/min — completing many SBRT sessions in under 2 minutes of beam-on time and enabling 4× the daily patient throughput of conventional linear accelerators.

Precision

kV and MV cone-beam CT imaging, online image review and sub-millimetre isocentric accuracy ensure the prescribed dose reaches the tumour — and not the surrounding tissue — at every fraction.

Versatility

One system covers the full radiotherapy caseload: 3D-CRT, IMRT, VMAT, SBRT, SRS and stereotactic radiosurgery for brain and spine — eliminating the need for multiple dedicated machines.

Ultra-fast delivery for high-volume oncology centres.

At 2,400 MU/min, TrueBeam completes many stereotactic body radiotherapy (SBRT) fractions in under two minutes of beam-on time. For African cancer centres managing large patient backlogs with limited machine capacity, this throughput advantage is transformative — more patients treated per machine per day, with no reduction in treatment quality.

Ultra-fast delivery for high-volume oncology centres.

Image-guided radiotherapy — every patient, every fraction.

TrueBeam's integrated imaging suite includes kV and MV cone-beam CT (CBCT), planar imaging and fluoroscopic tracking. Before each fraction, the clinical team reviews the patient's anatomy, matches it to the reference CT, and corrects position to sub-millimetre accuracy. This is not optional — it is the standard of care for all IMRT, VMAT and SBRT treatments, and it is included in every TrueBeam installation.

Image-guided radiotherapy — every patient, every fraction.

Commissioning, training and QA programme — managed by Jos•Hansen.

TrueBeam commissioning requires photon and electron beam data acquisition, multi-leaf collimator calibration, imaging system integration and treatment planning system (TPS) beam model commissioning. Jos•Hansen's certified medical physicists manage this entire process. Clinical staff receive hands-on training in TrueBeam operation, image review workflows, and motion management protocols. Ongoing QA includes machine output constancy, MLC transmission and Winston-Lutz end-to-end accuracy testing.

Commissioning, training and QA programme — managed by Jos•Hansen.

Technical specifications.

Energy range

6–18 MV photons · 6–22 MeV electrons

Maximum dose rate

2,400 MU/min (FFF mode)

Isocentric accuracy

<1 mm (mechanical, per IEC 60601)

Imaging

kV/MV CBCT · OBI · fluoroscopy · gating

Treatment modes

3D-CRT · IMRT · VMAT · SBRT · SRS · gated

Regulatory

FDA 510(k) cleared · CE Marked

Faster delivery than conventional LINACs — completing many SBRT courses in under 2 minutes of beam-on time

2,400

MU/min maximum dose rate in flattening-filter-free (FFF) mode for ultra-high dose rate SBRT delivery

<1mm

Isocentric mechanical accuracy per IEC 60601 — the geometric foundation of all IMRT, VMAT and SBRT treatments

Why TrueBeam.

4× throughput advantage

Ultra-high dose rate delivery completes many SBRT fractions in under 2 minutes — treating more patients per machine per day without reducing quality.

IGRT at every fraction

Integrated kV/MV CBCT and OBI verify patient positioning to sub-millimetre accuracy before every treatment — not just selected fractions.

Full application range

3D-CRT, IMRT, VMAT, SBRT, SRS — one TrueBeam system handles the complete radiotherapy caseload across all disease sites.

End-to-end delivery

Jos•Hansen manages TrueBeam installation, beam commissioning, TPS integration, staff training and scheduled preventive maintenance.

Partner with Jos Hansen

Talk to our procurement and operations teams about your next infrastructure, healthcare or scientific deployment.

100+
Years of Excellence
1,300+
Projects Completed
9+
African Countries
4
Operating Divisions